Partial circulatory support improves heart function in medically refractory heart failure patients
A pump the size of an AA battery weighing 25 grams provided
partial circulatory support and improved hemodynamics and cardiac function when
implanted in patients with medically refractory heart failure, according to research
presented at the American College of Cardiology's 58th annual scientific session.
The Synergy™ Pocket Micro-pump may expand the use of
circulatory assist devices in a large population of chronic heart failure patients
who are not sick enough to justify being implanted with a full support ventricular
assist device (VADs) but who have tried all other less invasive options without
success. Traditional ventricular assist devices provide full support, taking over
the work of the heart's main pumping chamber in end-stage heart failure patients
in or near cardiogenic shock. Their use is restricted because the surgery required
for their insertion is major, invasive and risky.
"Traditional VADs pump five to seven liters of blood
per minute and therefore, just by physical necessity, they have to be large,"
said Daniel Burkhoff, M.D., Ph.D, adjunct associate professor at Columbia University,
New York, and chief medical officer of CircuLite, Inc., developer of the Synergy
device. "Synergy, the smallest device being investigated in adults, supports cardiac
function by pumping just 2.5 to 3.0 liters of blood per minute."
"This study was done to determine if such partial support
would be adequate to provide long-term benefits in NYHA Class IIIb and early Class
IV patients."
In the study, 16 patients (13 males), mean age 52 years,
with a mean baseline ejection fraction of 20 percent, were implanted with the
Synergy™ pump. Before implantation, their mean arterial pressure was 71 mmHg,
mean pulmonary capillary wedge pressure was 29 mmHg, and mean cardiac index was
1.9 L/min/m2. The duration of their partial support was a median 81 days and ranged
from six to 213 days.
Thirteen of the 16 patients (81 percent) were alive at
three months. Of these, seven patients had right heart catheterization at 10.6
± 6 weeks. Increases in mean arterial pressure (70 ± 6 mmHg vs 80 ± 10 mmHg, p
= 0.04) and cardiac index (2.1 ± 0.4 vs. 2.9 ± 0.6, p = 0.02) with large reductions
in capillary wedge pressure (30 ± 5 vs. 16 ± 4, p = 0.002) were observed. Peak
VO2 increased by 3.0 ± 0.5 ml/kg/min (10.7 ± 2.2 vs. 13.7 ± 2.2, p = 0.008).
"Prior studies have shown that when you implant a full
ventricular support device, patients' hemodynamic function and heart function
improve. The significance of this research is that we have shown for the first
time that with long-term partial circulatory support, patients' hemodynamic condition
is significantly improved and these improvements are sustained over time," Burkhoff
said. "This is real proof of concept that the use of partial circulatory support
is feasible and likely to be clinically meaningful. The ultimate goal is to use
partial circulatory support not as a bridge to transplant, but as a long-term
therapy. In Europe, the distinction between bridge to transplant and long-term
support is blurred because the wait times are so long for a heart that patients
can be supported for six to 24 months or more, even in a bridge situation."
|